Commercial & Industrial Solar

Commercial & Industrial Solar

Electricity bills make up a substantial share of operational expenses for modern enterprises. Access Con Solar delivers high-yield rooftop and ground-mounted solar power plants engineered specifically for manufacturing plants, warehouses, hospitals, educational institutions, and commercial complexes across Jharkhand. We help businesses slash grid power tariffs and lock in predictable, levelized energy costs for decades.

Key Financial & Operational Benefits:

Massive Cost Reduction: Cut daytime utility power consumption costs by up to 70% to 80% with self-generated clean solar energy.

Accelerated Depreciation Tax Benefits: Save on corporate income tax by claiming up to 40% accelerated depreciation in the first year under Section 32 of the Income Tax Act.

Fast ROI within 3 to 4 Years: Offset high commercial grid tariffs and recover your complete capital investment rapidly, followed by 20+ years of free electricity.

JBVNL Net Metering & HT Synchronization: Export surplus units directly into the utility distribution network through seamless HT/LT bi-directional net metering approvals.

Service Process
  • Detailed site audit, load profiling, and shadow analysis.
  • Custom electrical CAD design and generation simulations.
  • Complete JBVNL approvals, CEIG inspection, and net metering.
  • Heavy-duty structural fabrication and Tier-1 module installation.
  • System commissioning, IoT remote monitoring, and AMC support.

Capacity, Generation & Financial Returns (Commercial & Industrial)

System Capacity Daily Generation Rooftop Space Required Tax Benefit (Sec 32) Best Suited For
10 kW to 25 kW 40 - 100 Units / Day 1,000 - 2,500 sq. ft. 40% Depreciation Petrol Pumps, Clinics, Hotels & Retail Stores
25 kW to 50 kW 100 - 200 Units / Day 2,500 - 5,000 sq. ft. 40% Depreciation Schools, Hospitals, Banquet Halls & Offices
50 kW to 100 kW+ 200 - 450+ Units / Day 5,000 - 10,000+ sq. ft. 40% Depreciation Warehouses, Cold Storage, Factories & Mills

How It Works

  • Direct Heavy Load Operation: High-capacity commercial arrays produce high-voltage DC power that converts via 3-phase inverters to run heavy industrial machinery directly during peak tariff hours.
  • Grid Synchronization: The plant synchronizes directly with JBVNL HT/LT supply to provide seamless power without dropping factory lines.
  • Weekend Net Metering: Excess power generated during non-working days or light production automatically feeds into the grid to generate tariff credits on your monthly power bills.

Who Is It For?

Engineered for commercial businesses, industrial manufacturing units, cold storage facilities, private institutions, and hospitals across Jharkhand looking to drastically cut commercial electricity costs, eliminate expensive diesel generator fuel bills, and maximize income tax savings via accelerated depreciation[cite: 7].

Can a commercial solar plant run heavy factory machinery?

Yes. Commercial systems synchronize seamlessly with your 3-phase grid power to run inductive machinery, HVAC chillers, compressors, and high-load assembly lines without voltage fluctuations.

What is the typical ROI period for commercial solar?

Commercial solar investments usually break even within 3 to 4 years due to high industrial tariff savings and accelerated tax write-offs, providing 20+ years of free power afterward.

Can businesses claim tax benefits on solar installations?

Yes. Under Section 32 of the Income Tax Act, commercial and industrial enterprises can claim up to 40% accelerated depreciation in the first year to significantly reduce corporate income tax.

How does net metering work for factories during holidays or weekends?

On non-working days or low-operation hours, surplus generation is automatically exported to the JBVNL grid through the bi-directional HT/LT net meter to build energy bill credits.

Can we monitor the daily power output of a large solar setup?

Yes. Every commercial project includes integrated IoT/SCADA monitoring that provides real-time generation statistics, fault alerts, and performance metrics directly on a mobile or desktop dashboard.

Service Options
1

Site Audit & Load Profiling

Analyze historical 12-month power bills, peak demand patterns, and conduct drone/3D structural roof integrity checks.
2

Advanced Engineering & CAD Design

Design custom 3D string layouts, simulate generation yields, and size commercial 3-phase inverters to match facility voltage.
3

DISCOM Liaison & Clearances

Prepare technical documentation and manage full liaisoning for JBVNL feasibility clearance, load approvals, and CEIG statutory inspection.
4

Heavy Structure Mounting

Fabricate and anchor hot-dip galvanized elevated structures built to endure heavy wind loads and protect industrial tin/RCC sheds.
5

Module & HT/LT Integration

Mount Tier-1 high-wattage bifacial PV modules, connect industrial string inverters, and integrate AC/DC protection panels with multi-point earthing.
6

Net Metering & Commissioning

Synchronize the bi-directional HT/LT net meter with the JBVNL power grid, integrate IoT SCADA monitoring, and commission the plant for live production.